We’re so glad to share with you that 5pcs valves did the Cryogenic valves successfully last week. More details as below:
Material:CF8 Connection:BW Size:4”-8” Pressure:150#-600# Normal Test:IS05208
①100% Nitrogen Shell Test Pressure:1, 1PN
CLass 150:2,2Mpa Class 300:5,7 Class 600:11,4
②100% Nitrogen seat Test Pressure:1,1PN
CLass 150:2,2Mpa Class 300:5,7 Class 600:11,4
③100% Nitrogen seat Test Pressure:1,1PN Pressure:0,5-0,7Mpa
Crypgenic Test IS0 28921-1 Temperature:-196℃
①Low Pressure Seat Test: Pressure 2bar (open and close 5 times)
②High Pressure Sest Test
Class150I(SA10EO):4,8bar Class300(SB10EO):12,4bar
Class600(SC10EO):24,8
③High Pressure Seat Test:
Class150(SA10EO):4,8bar Class300(SB10EO):12,4bar
Class600(SC10EO):24,8
We’re vwry professional in industrial valves and cryogenic valves,if you have any pro ject regarding them pls do not hesitate to contact us.